Table 7 The diagnostic results of each study included in the meta-analysis

From: Diagnostic accuracy of palpation versus ultrasound-guided fine needle aspiration biopsy for diagnosis of malignancy in thyroid nodules: a systematic review and meta-analysis

Study (year)

Technique

Sample size

True Positives

False Positives

False Negatives

True Negatives

Takashima et al. (1994) [9]

PGFNAB

34

21

1

3

9

USGFNAB

99

64

3

3

29

Hatada et al. (1998) [11]

PGFNAB

66

23

1

19

23

USGFNAB

60

22

1

11

26

Danese et al. (1998) [10]

PGFNAB

522

79

136

7

300

USGFNAB

535

99

126

3

307

Carmeci et al. (1998) [12]

PGFNAB

41

17

11

2

11

USGFNAB

15

10

4

0

1

Solymosi et al. (2001) [23]

PGFNAB

317

19

101

6

191

USGFNAB

380

35

102

3

240

Goudy et al. (2005) [13]

PGFNAB

18

5

1

0

12

USGFNAB

11

2

5

0

4

Cesur et al. (2006) [14]

PGFNAB

18

4

3

2

9

USGFNAB

22

6

2

1

13

Izquierdo et al. (2006) [15]

PGFNAB

23

7

5

4

7

USGFNAB

5

3

1

0

1

Can et al. (2008) [16]

PGFNAB

15

2

1

0

12

USGFNAB

22

8

3

0

11

Krishnappa et al. (2013) [17]

PGFNAB

25

6

1

5

13

USGFNAB

25

9

1

2

13

Sharma et al. (2017) [19]

PGFNAB

49

5

6

1

37

USGFNAB

80

3

3

1

73